Page 152 - GRIHA Manual Volume IV - Introduction to National Rating System
P. 152
Building operation and maintenance 143



Table 2 Illumination levels recommended by the National Building Code-2005

Area NBC Recommended
Ofice area_enclosed 300–500
Ofice area_open plan 300–500
Corridor 50–100–150
Restroom 100–150–200
Conference 300–500
Reception 200–300–500
Library 200–300–500
Source National Building Code - 2005

Main instruments for energy and comfort audit

Different types of instruments are used for conducting energy audits. Following is a list of different
types of instruments that are used for conducting audits along with their function.


Instrument name Function Photograph





Thermography imager To measure temperature gradient over
surface










Thermohygrometer Temperature and RH hourly data
collection












Infrared gun Instant temperature over the surface
   147   148   149   150   151   152   153   154   155   156   157